typical applications ? optical network switching ? optical network protection ? optical network restoration ? transmission equipment protection ? loopback diagnostic testing ? network test access ? fddi bypass ? local area network bypass features ? high reliability ? bidirectional ? integral position sensor ? small size ? ttl interface ? < 10 ms switching time ? 0.6 db typical insertion loss ? pcb mountable ? latching and non-latching con?gurations ? high loss path for bypass & loopback testing (option) ? fail-safe return to bypass mode on power loss (non-latching) multimode fiber optic switch digital - latching - status sensor 1213 north main street ? blacksburg, va 24060-3127 800-336-2112 ? fax 540-557-6400 www.moog.com ? e-mail: mcg@moog.com the switching mechanism is available in either a latching or non-latching version with an integral position sensor for both versions. switches are available in on/off, 1x2 and 2x2 con?gurations. there is also a high attenuation version of the 2x2 switch used for node bypass applications. the silicon based electromechanical multimode switch uses a moving mirror actuation scheme to allow light to pass through the switch on activation or to be blocked/ diverted when the switch is deactivated in a non-latching con?guration. this makes the switch particularly well suited for fail-safe bypass applications. a standard pcb footprint allows the switch to be conveniently mounted. the standard switch is equipped with 1m 62.5/125 m multimode ?ber pigtails with no connectors, but a variety of ?ber and connector options are available. for more information about our entire line of ?ber optic products, please visit our web site at www.moog.com . fo4649
800-336-2112 ? fax 540-557-6400 ? www.moog.com ? e-mail: mcg@moog.com 1213 north main street ? blacksburg, va 24060-3127 speci?cation and information are subject to change without prior notice. ? 2005 moog components group msg80027 7/05 1-3, 2-4 logic high 1-2, 3-4 logic low pin number description 1 set 2 vcc 3 gnd 4 rst 5 status all dimensions are in inches. *loss without connectors min typ max unit environmental ratings operating temperature range -10 CC 70 c storage temperature range -40 CC 85 c humidity (non-condensing) CC CC 95 % rh mechanical life 10 CC CC m cycle characteristics vcc (also available w/ 3.3v and 12v) CC 5 CC v switching time CC 5.0 10.0 ms loss* 1-3 port CC 0.7 0.8 db loss* 2-4 port CC 0.7 0.8 db loss* 3-4 port CC 0.8 1.0 db loss* 1-2 port CC 0.8 1.0 db loss* 1-2 port (high atten. bypass) 4.5 5.5 6.0 db crosstalk 60 CC CC db (bypass mode) specifications part numbering configurations typical switch configuration (2x2) switch pin configuration fo4649 - - - - code l n code d code st y le x n c none fc fc/pc sc sc/pc code lc lc/p c 3 st st/p c 5 x x s p ecial 1 x a 50/125/900 m code b 62.5/125/900 m 01 c 100/140/900 m 02 x special 01 02 b2 ( 1 hi g h attenuation b y pass path ) 2 voltag e 3.3 v 5 v 2 t y pe latchin g non latchin g t y pe di g ital ( tt l ) contact mf g 3 digit code for length in centimeters (+10/-00 cm). standard length is 100 cm maximum length equals 300 cm 12 v # 1 othe r 2 1 # code code d - configura tion interf ace activ a tion vol t age input por ts output por ts connect or fiber pigt ail length
|